Productos

Fusibles

  • Acaba de agregar este producto al carrito:

    FUSIBLE A2D-R - Class RK1 - Time-Delay

    0 out of 5

    FUSIBLE A2D-R – Class RK1 – Time-Delay

    Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 “no damage” protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace obsolete 250V Class H, K or RK5 fuses already installed in the field.

    ver

  • Acaba de agregar este producto al carrito:

    Fusible A4BQ - Class L - Time-Delay

    0 out of 5

    Fusible A4BQ – Class L – Time-Delay

    Amp-Trap 2000® A4BQ fuses are 20% more current-limiting than any
    other Class L fuse on the market. When correctly coordinated, they
    bring a superior level of protection to service entrance equipment.
    Downstream circuit components have maximum protection against
    short circuit let-thru current. A4BQ’s built-in, 4-second time-delay
    characteristic (at 500% of rated current) accommodates harmless
    inrush currents without nuisance opening.

    ver

  • Acaba de agregar este producto al carrito:

    Fusible AJT Time-delay/ Class JAmp-Trap 2000

    0 out of 5

    Fusible AJT Time-delay/ Class JAmp-Trap 2000

    Los fusibles AJT con retardo de tiempo Amp-Trap 2000 brindan protección IEC tipo “2” (sin daños) a los circuitos principal, alimentador y de derivación, para todos los tipos de cargas; sin embargo, requieren solo la mitad del espacio de montaje necesario para 600V UL Class Fusibles RK. Las características de retardo de tiempo manejan las corrientes de entrada del motor sin disparos molestos. Su capacidad de limitación de corriente y su amplio rango de calificaciones brindan una excelente protección contra sobrecorriente para todas sus aplicaciones. Un indicador opcional de fusible fundido y un microinterruptor está disponible en los fusibles tipo cuchilla (70 a 600 A) para una indicación visual y / o remota de fusible fundido.

    ver

  • Acaba de agregar este producto al carrito:

    Current-Limiting Power Fuses 9F62 Series EJO-1 .15.5KV

    0 out of 5

    Current-Limiting Power Fuses 9F62 Series EJO-1 .15.5KV

    General Purpose current-limiting fuses are designed to interrupt the high-fault currents and also the low-fault
    currents down to approximately 1.6 to 2.2 times their continuous current rating. This fuse is defined in the IEEE
    Std C37.40 -1993 (3.1.57) as “A fuse capable of interrupting all currents from the rated interrupting current
    down to the current that causes melting of the fusible element in no less than one hour.” These fuses can be used
    outdoors without any protecting enclosure. Available from 5.5 to 15.5kV and 20 to 900A.

    ver

Materiales Eléctricos Industriales

  • Acaba de agregar este producto al carrito:

    Aisladores polímerico Pin

    0 out of 5

    Aisladores polímerico Pin

    ver

  • Acaba de agregar este producto al carrito:

    Pararrayos Polimericos

    0 out of 5

    Pararrayos Polimericos

    ver

  • Acaba de agregar este producto al carrito:

    Terminaciones HVT Termocont. 5KV a 35kV

    0 out of 5

    Terminaciones HVT Termocont. 5KV a 35kV

    The HVT-Z high voltage termination system features a new, co-extruded one-piece termination.
    The main termination component consists of the proven Raychem non-tracking tube together
    with a co-extruded stress control grading layer. This stress control layer is based on ceramic
    semi-conductor technology (ZnO) and provides superior discharge and impulse performance.
    When the tubing is shrunk down, the coating softens and sticks to irregular surfaces, providing
    moisture seals as well as electrical stress control.

    ver

WhatsApp Logo